ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2021 , Vol 16 , Num 1
Abstract Free Full Text Similar Articles Mail to Author
Effects of Static Cyclotorsion Compensation of Refractive Outcomes and Level of Vision in Excimer Laser Surgery
Kemal OZULKEN1, Mehmet Ozgur CUBUK2, Erdem YUKSEL3
1Ophthalmologist, MD, Ophthalmology Department of TOBB University, ETÜ Medicine School, Ankara, Turkey
2Ophthalmologist, MD, Ophthalmology Department of İstanbul Training and Research Hospital, İstanbul, Turkey
3Associate Prof., MD, Ophthalmology Department of Kastamonu University, Kastamonu, Turkey
DOI : 10.37844/glauc.cat.2021.16.7 Purpose: To evaluate the reliability and reproducibility of static cyclotorsion compensation (SCC) measurements made by software of WaveLight EX500 Excimer laser in patients undergoing Laser-Assisted in Situ Keratomileusis (LASIK) procedure.

Materials and Methods: A retrospective study was designed to compare the refractive and visual outcomes of LASIK procedure with or without SCC. Patients with astigmatism greater than or equal to 0.50 D that undergone LASIK surgery with SCC were included in the Group 1, without SCC were included in Group 2. The astigmatism of eyes in group 1 was also classifi ed according to axis as with the rule (WTR), against the rule (ATR) and oblique. The preoperative and postoperative spherical error, astigmatic error, and axis of astigmatism were compared between different groups. Subgroup analysis of group 1 was performed between different types of astigmatism groups.

Results: Three hundred ninety-eight eyes of 199 patients were included in Group 1 and 126 eyes of 63 patients were included in Group 2. Postoperative spherical error was -0.003±0.36 (-1.00 +1.50) in group 1 and +0.11± 0.65 (-0.75 +1.50) in group 2 (p=0.04), Postoperative astigmatic error was -0.40±0.22 (-1.25 +0.50) in group 1 and -0.85± 0.22 (-1.25 -0.50) in group 2, (p=0.001). The mean magnitude of SCC was -0.95°±4.1. Postoperative astigmatic error was signifi cantly higher in WTR than ATR and oblique group (p=0.044, p=0.039, respectively)

Conclusion: The cyclotorsion is reasonably compensated with using software of WaveLight EX500 Excimer in conjunction with the Wavelight Topolyzer Vario. Refractive outcomes could be better in the oblique group. Keywords : Cyclotorsion, Laser-Assisted in Situ Keratomileusis, With the rule astigmatism, Against the rule astigmatism, Oblique astigmatism

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact