ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2007 , Vol 2 , Num 2
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Do Central Corneal Thickness Measurements with Ultrasonic Pachymeter Show Variations over Time?
Esra GÜNEY TEFEKLİ1, Belgin İZGİ2
1İstanbul Üniversitesi İstanbul Tıp Fakültesi Göz AD., İstanbul, Uzm. Öğr.
2İstanbul Üniversitesi İstanbul Tıp Fakültesi Göz AD., İstanbul, Prof. Dr.
Purpose: To evaluate reliability and reproducibility of central corneal thickness (CCT) measurement by ultrasonic pachymeter over time in experienced hands.
Materials and Methods: Seventeen patients with primary open angle glaucoma (PAAG) or ocular hypertension and 13 healthy volunteers were enrolled in the study. CCT was measured using an ultrasonic pachymeter (OcuScan™ Alcon, Inc, Irvine, California) by one observer, experienced in the technique, and get used with the same device for more than 6 months. Repeat readings were taken at consecutive outpatient visits over one month period.
Results: The mean time period between reading 1 and 2 was 30 days. The readings did not show significant difference over the 1-month period. Overall, the mean+SD CCT measurement in the right eye was 549+44.5 μm on the first visit and 540.5+44.3 μm on the second visit (p=0.9). The mean CCT in the left eye was 552+47.6 μm on the first visit and 552+46.6 μm on the second (p=0.9). Consecutive CCT measurements by ultrasonic pachymeter in both healthy subjects and patients with ocular hypertension or PAAG revealed no significant differences separately.
Conclusions: Our results indicate that CCT measurement by ultrasonic pachymeter is highly reliable, and that repeated measurements do not show variations over time in experienced hands.
Keywords : Glaucoma, central corneal thickness, ultrasonic pachymeter