ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2007 , Vol 2 , Num 1
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Reproducibility in Measurements of Central Corneal Thickness with Ultrasonic Pachymeter
Esin F. BAŞER1, Eray ESER2, Barış TOPRAK3, Ziya KAYA2, Cenap GÜLER1
1Celal Bayar Üniversitesi Tıp Fakültesi Göz Hastalıkları A.D., Manisa, Prof. Dr.
2Celal Bayar Üniversitesi Tıp Fakültesi Göz Hastalıkları A.D., Manisa, Araş. Gör.
3Celal Bayar Üniversitesi Tıp Fakültesi Göz Hastalıkları A.D., Manisa, Doç. Dr.
Purpose: To assess whether central corneal thickness (CCT) measurements with ultrasonic pacyhmeter is reproducible among different observers and repeated measurements of a single observer.

Materials and Methods: To assess the reproducibility among different observers, CCT measurements were performed on 50 eyes by 3 observers of varying experience (1. most experienced, 2. moderately experienced, 3. least experienced). A single observer also performed repeated mesaurents of CCT on 50 eyes in order to assess the reproducibility of the same observer’s measuremens. The reproducibility of measurements were analyzed statistically by calculating intraclass correlation coefficient (ICC). In addition, percentage of mesaurement differences equal or greater than 10 μm were determined.

Results: The mean CCT mesaurements of 1., 2. and 3. observers were 548, 549 and 552 μm for right eyes and 547, 548 and 550 μm for left eyes, respectively. ICC was 0.99 between 1. and 2. observers’, 0.98 between 3. and other observers’ measurements for both eyes. Percentage of measurements equal or greater than 10 μm were 4% between 1. and 2. observers, 13% between 3. and other observers. Repeated measurements of a single observer were 550, 550 ve 550 μm for right eyes, and 549, 550 ve 549 μm for left eyes, respectively. ICC was 0.98 for repeated measurements of both eyes by this observer. Also, the percentage of measurements equal or greater than 10 μm were 4% for repeated measuerements of this observer.

Conclusion: Measurements of CCT by means of ultrasonic pachymetry among different observers and repeated measurements of a single observer are reproducible; however inexperienced observers tend to perform thicker measurements. Keywords : Central corneal thickness, pachymetry, reproducubility