ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2016 , Vol 11 , Num 1
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Comparison of Higher Order Aberrations in Eyes in Which Two Commonly Used Hydrophobic Spherical Intraocular Lenses are Implanted
Faruk KAYA1, İbrahim KOÇAK2, Ali AYDIN3, Hakan BAYBORA1, Mustafa ELİAÇIK2
1M.D. Special Nisa Hospital, Eye Clnic, Istanbul/TURKEY
2M.D. Asistant Professor, Medipol University Faculty of Medicine, Department of Ophthalmology, Istanbul/TURKEY
3M.D. Associate Professor, Medipol University Faculty of Medicine, Department of Ophthalmology, Istanbul/TURKEY
Purpose: To compare two hydrophobic spherical acrylic lenses in terms of their effects on higher order aberrations.

Materials and Methods: In this prospective and randomized study 48 eyes of 38 patients who underwent cataract surgery with phacoemulsification and hydrophobic acrylic IOL implantation were included. Two hydrophobic spherical IOL groups were made up. In group 1, Focus force F260, Zaraccom (Anadolu Tıp Teknolojileri, Sivas, Turkey) lenses were implanted in 24 eyes. In group 2, Acrysof SA 60 (Alcon Lab. Inc.,FtWorth, Tex, USA) were used in 24 eyes. Aberrometry was performed on postoperative 90 thday and two groups were compared for higher order aberrations.

Results: Postoperative total RMS value was 3.18±2.48 for Zaraccom group. The other values were 0.17±0.19 for higher order RMS, 0.04±0.06 for coma, -0.004±0.07 for spherical aberration, and 0,08±0,09 for trefoil. The results for Acrysof SA 60 group were 1.44±1.40; 0.24±0.1; 0.13±0.08; 0.05±0.06; 0.14±0.08 for total RMS value, higher order RMS value, coma, spherical aberration and trefoil respectively.

Conclusion: There was not statistically significant difference between two groups for all aberrometry parameters (p>0.05). Keywords : Higher order aberrations, phacoemulsification, zaraccom, Acrysof SA 60