ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2015 , Vol 10 , Num 4
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Comparison of Central Corneal Thickness Measurements of Nidek Al-Scan, Galilei G4 Dual Scheimpflug Analyzer and Cirrus HD-OCT
Mehmet Serdar DERVİŞOĞULLARI1, Yüksel TOTAN2, İsa YUVACI3, Fatma Betül GÜRAĞAÇ4
1M.D Asistant Professor, Turgut Ozal University Faculty of Medicine, Department of Ophthalmology, Ankara/TURKEY
2M.D Professor, Turgut Ozal University Faculty of Medicine, Department of Ophthalmology, Ankara/TURKEY
3M.D, Kayseri Training and Research Hospital, Eye Clinic, Kayseri/TURKEY
4M.D, Turgut Ozal University Faculty of Medicine, Department of Ophthalmology, Ankara/TURKEY
Purpose: To compare the central corneal thickness (CCT) measurements of three different devices.

Material and Methods: CCT was measured in one eye of 41 healthy subjects (age: 29.6±7.23 range:20-47), using the Nidek AL-Scan, Galilei G4 Dual Scheimpflug Analyzer and Cirrus HD-OCT (Cirrus Version 6.0). The agreement between the measurements of three devices was assesed using the one way ANOVA test. To assess the interexaminer reproducibility, two different examiners consecutively obtained CCT measurements in 23 eyes with Nidek AL-Scan, Galilei Dual Scheimpflug Analyzer and Cirrus HD-OCT.

Results: Mean±SD values for CCT using the Nidek AL-Scan, Galilei Dual Scheimpflug Analyzer and Cirrus HD-OCT were 541.04±34.91 μm, 541.56±31.05 μm, and 541.73±33.83 µm respectively. There was no statistically significant difference between these three devices at measuring CCT (p=0.98). Intraclass correlation between different observers was fine (>0.9 for each device) and Bland Altman plots of observers' measurements with each device showed good agreement.

Conclusions: Nidek AL-Scan, Galilei G4 Dual Scheimpflug Analyzer and Cirrus HD-OCT provide CCT measurements that are in agreement with each other and with the published values for CCT in human subjects. CCT measures from these instruments should be used interchangeably. Keywords : Central corneal thickness, optical biometer, scheimpflug camera, optical coherence tomography

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact