ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2015 , Vol 10 , Num 4
Turkish Abstract Abstract PDF Similar Articles Mail to Author
The Effect of Supraglottic Airway Insertion on Intraocular Pressure in Rabbits
İsmail ERŞAN1, Baran GENCER1, Sedat ARIKAN1, Hüseyin TOMAN2, Selçuk KARA1, Mesut ERBAŞ2, Hasan Ali TUFAN3
1M.D. Asistant Professor, Canakkale 18 Mart University Faculty of Medicine, Department of Ophthalmology, Canakkale/TURKEY
2M.D. Asistant Professor, Canakkale 18 Mart University Faculty of Medicine, Department of Anesthesiology and Reanimation, Canakkale/TURKEY
3M.D. Associate Professor, Canakkale 18 Mart University Faculty of Medicine, Department of Ophthalmology, Canakkale/TURKEY
Purpose: To evaluate the changes in intraocular pressure (IOP) in rabbits while under general anesthesia before and after insertion of laryngeal mask airway (LMA), Cobra perilaryngeal airway (Cobra PLA), and V-gel laryngeal mask airway.

Materials and Methods: Eighteen New Zealand rabbits weighing between 2.0-3.50 kg were randomized into three groups of LMA, Cobra PLA, and V-gel according to body weight. After anesthesia induction with intramuscularly 35 mg/kg ketamine and 5 mg/kg xylazine, intravenous 1 mg/kg rocuronium was used for neuromuscular blockage. IOP were measured just before insertion of airway devices and at 1., 3., 5., 10. min after insertion of airway devices by Tonopen®. Friedman test were used to determine the statistically significance between the measurements in all groups. A p value <0.05 was considered to be statistically significant.

Results: Before the insertion of airway devices the mean IOPs in LMA, Cobra PLA, and V-Gel groups were 8.17±2.64, 8.17±4.45, 9.00±1.67 mmHg, respectively. The mean IOPs at 1.min after insertion of airways were measured 6.00±0.63, 7.50±1.38, 6.83±1.17 mmHg, respectively. The changes of IOPs with the insertion of airways in all groups did not reach statistically significance (p>0.05).

Conclusion: LMA, Cobra PLA, and V-Gel were found as easy and fast applicable airway devices in rabbits anesthesia. Insertions of these supraglottic airway devices are not associated with an increased IOP response in rabbits. Our result needs to be supported with future studies in human. Keywords : Rabbit, intraocular pressure, laryngeal mask airway, cobra perilaryngeal airway, V-gel laryngeal airway