ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2014 , Vol 9 , Num 2
Turkish Abstract Abstract PDF Similar Articles Mail to Author
The Effect of Preloaded Intraocular Lens Injection System On Cataract Surgery Times
İzzet CAN1, Hasan Ali BAYHAN2, Seray ASLAN BAYHAN2, Ersin MUHAFIZ3, Şükran BAKDEMİR3
1M.D. Professor, Special Maya Eye Clinic, Ankara/TURKEY
2M.D. Asistant Professor, Bozok University Faculty of Medicine, Department of Ophthalmology, Yozgat/TURKEY
3M.D., Bozok University Faculty of Medicine, Department of Ophthalmology, Yozgat/TURKEY
Purpose: To evaluate the contribution of preloaded intraocular lenses (IOL) to phacoemulsification surgery times.

Material and Methods: In this prospective comparative study, Physiol IOLs with preloaded system in 20 patients of group 1 and Acriva IOLs with manual cartridge-injector system in 20 patients of group 2 were implanted. The period from the beginning to the IOL implantation stage was recorded in groups as A1 and A2 respectively. Afterwards from that time to the end of the surgery were also determined as B1 and B2 based on real time video recordings. Mean total operation times were determined as C1 and C2 by summing up these times.

Results: While A1 and A2 were compatible with each other (p=0.787), avarage B1 time, including IOL implantation stage, was 193.3±20.6 sec and B2 was 212.9±49.1 sec (p=0.448). C1 and C2 showing mean total operation times were 625.7±99.8 sec and 654.7±184.8 sec (p=0.833) respectively.

Conclusion: When compared with the manual loaded cartridge-injector IOL systems, preloaded IOLs reduced the operation time, whereas this reduction was not statistically significant. Keywords : Cataract surgery, preloaded intraocular lens injector systems