TJ-CEO 2015 , Vol 10 , Num 4
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Changes in Corneal Biomechanical Properties After Phacoemulsification Surgery
Sevil KARAMAN ERDUR1, Uğur ÇELİK2, Hakan EREN3, Ebru Demet AYGIT4, Hülya GÜNGEL5
1M.D. Istanbul Medipol University Medical Faculty Department of Ophthalmology, Istanbul/TURKEY
2M.D. Taksim Training and Research Hospital, Eye Clinic, Istanbul/TURKEY
3M.D. Associate Professor, Dunya Eye Hospital, Istanbul/TURKEY
4M.D. Beyoglu Eye Training and Research Hospital, Istanbul/TURKEY
5M.D. Professor, Samatya Training and Research Hospital, Eye Clinic, Istanbul/TURKEY
Purpose: To evaluate corneal viscoelastic and intraocular pressure (IOP) changes measured by an ocular response analyzer (ORA) after phacoemulsification and intraocular lens (IOL) implantation.

Materials and Methods: Sixty-three eyes scheduled for cataract surgery were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated IOP (IOPg) were measured by ORA preoperatively and postoperative 1st week, 1st month and 3rd month. Central corneal thickness (CCT) was measured using Orbscan II.

Results: The mean CH decreased significantly from 10.28±1.61 mmHg preoperatively to 9.57±1.70 mmHg at 1 week (p=0.004) however increased to 10.21±1.61 mmHg at 3 month (p=0.9). The mean CRF decreased significantly from 10.61±1.89 mmHg preoperatively to 9.61±1.92 mmHg at 1 week (p=0.004) however increased to 10.51±1.69 mmHg at 3 month (p=0.8). The mean preoperative IOPg was decreased significantly in all postoperative measurements, (1st week p=0.03, 1st month p=0.01, 3rd month p=0.009). The mean preoperative IOPcc did not change significantly by first week and 1st month postoperatively (p=0.8, p= 0.2), however decreased significantly at 3rd month control. (p=0.04)

Conclusions: Even the CH, CRF values decreased significantly in early postoparative period after phacoemulsification surgery, there was no change according to preoperative values in 3 months follow up. Mean İOPg and IOPcc values decreased in the postoperative period. That was showing that corneal biomechanical properties are influenced by phacoemulsification and IOL implantation. Keywords : Corneal biomechanical properties, standard clear corneal phacoemulsification surgery, ocular response analyzer, ORA, corneal hysteresis