ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2015 , Vol 10 , Num 3
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Axial Length Measurement with IOL Master in Silicone Oil-filled Eyes
Mahmut KAYA1, Gül ARIKAN2, Müzeyyen UYAR GÖĞÜŞ1, Ferit Hakan ÖNER3, Ali Osman SAATCİ3
1M.D. Dokuz Eylül University Faculty of Medicine, Department of Ophthalmology, Izmir/TURKEY
2M.D. Associate Professor, Dokuz Eylül University Faculty of Medicine, Department of Ophthalmology, Izmir/TURKEY
3M.D. Professor, Dokuz Eylül University Faculty of Medicine, Department of Ophthalmology, Izmir/TURKEY
Purpose: To evaluate the accuracy and reliability of axial length measurements with IOL Master in silicone oil-filled eyes.

Material and Methods: A prospective study was performed in 31 silicone oil - filled eyes of 31 patients that underwent silicone oil removal surgery. To evaluate the accuracy and safety of axial length measurement with IOL Master in silicone oil-filled eyes, axial length measurements with IOLMaster was performed before and two months after the silicone oil removal surgery. Axial length values before and after the silicone oil removal surgery were compared.

Results: Mean age was 61.4±8.7 years (Range, 47-85 years). Of the 31 eyes, 11 (35%) were phakic, 20 (65%) were pseudophakic. The mean axial length was 25.29±1.34 mm (Range 23.39-28.65 mm) before silicone oil removal. The mean axial length was 25.12±1.26mm (Range 22.49-27.74 mm) after silicone oil removal. No statistically significant difference was found between the groups (p=0.077). In the subgroup analysis, mean axial length before and after silicone oil removal was 25.55±1.68 mm (Range 23.87-28.65 mm) and 25.50±1.34 mm (Range 23.78-27.74 mm) in phakic eyes (p=0.477), and 25.15±1.13 mm (Range 23.39-27.39 mm) and 24.91±1.20 mm (Range 22.49-27.30 mm) in pseudophakic eyes (p=0.049), respectively.

Conclusion: The present study shows that measurement of axial length in silicone oil-filled eyes with IOL Master is reliable. Keywords : Axial length, IOL Master, silicone oil-filled eye

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact