ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2014 , Vol 9 , Num 2
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Evaluation of Anterior Segment Parameters Using Optical Low Coherence Reflectometry in Patients with Pseudoexfoliation Syndrome
Mehmet Özgür ZENGİN1, Eyyüp KARAHAN2, İbrahim TUNCER2, Esat ÇINAR1, Cem KÜÇÜKERDÖNMEZ3
1M.D. Asistant Professor, İzmir University Faculty of Medicine, Department of Ophthalmology, İzmir/TURKEY
2M.D., Special Alfa Eye Hospital, İzmir/TURKEY
3M.D. Associate Professor, İzmir University Faculty of Medicine, Department of Ophthalmology, İzmir/TURKEY
Purpose: The aim was to evaluate anterior segment parameters in eyes with pseudoexfoliation (PEX) syndrome to that of their clinically unaffected fellow eyes and normal control eyes with the optical low-coherence reflectometry (OLCR).

Materials and Methods: Twenty-three patients with unilateral PEX syndrome and 23 normal subjects were studied. Eyes were separated into those with PEX (group 1), their clinically unaffected fellow eyes (group 2), and normal eyes (group 3). Anterior chamber depth (ACD), central corneal thickness (CCT), lens thickness (LT), white-to-white distance and pupil diameters were compared between groups.

Results: Although anterior chamber depths in the group 1 and group 2 were significantly lower than the group 3 (p<0.05), there was no statistically significant difference between the group 1 and the group 2 in means of ACD values (p>0.05). There were no statistically significant differences among group 1, group 2 and the control group in mean values of LT, white-to-white distance, CCT and pupil diameters (p>0.05).

Conclusions: In this study, the PEX patients had significantly smaller ACD than normal control eyes. There were no significant differences in the means of other parameters among eyes with PEX to that of their clinically unaffected fellow eyes and normal control eyes. Keywords : Optical low-coherence reflectometry, pseudoexfoliation syndrome

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact