ISSN : 3023-7505
  • Home
  • About
    • About The Journal
    • Instructions for Authors
    • Privacy Policy
    • Reviewer Process
    • Research and Publication Ethics
  • Editorial Board
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2010 , Vol 5 , Num 1
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Comparasion of Reliability and Effectiveness of the Foldable and Non-foldable Iris-fixated Phakic Intraocular Lens for the Correction of High Myopia
Ahmet Taylan YAZICI1, Necip KARA2, Ercüment BOZKURT1, Yusuf YILDIRIM2, Hüseyin DÜNDAR2, Vedat KAYA3, Ahmet DEMİROK4, Ömer Faruk YILMAZ4
1Beyoğlu Göz Eğitim ve Araştırma Hastanesi İstanbul, Uzm. Dr.
2Beyoğlu Göz Eğitim ve Araştırma Hastanesi İstanbul, Asist. Dr.
3Beyoğlu Göz Eğitim ve Araştırma Hastanesi İstanbul, Doç. Dr.
4Beyoğlu Göz Eğitim ve Araştırma Hastanesi İstanbul, Prof. Dr.
Purpose: To compare the safety and efficacy of the foldable (Artisan/Veriyse) and nonfoldable (Artiflex) iris-fixated phakic intraocular lens (IF-PIOL) for the correction of high myopia
Materials and Methods: Twenty seven eyes of 17 patients with miyopia from -6 D to -20.5 D were reviewed retrospectively. A foldable or nonfoldable IF-PIOL were implanted to all of the patients. Refractive outcomes were compared between two lens groups at one year after the operation.
Results: In this study, 12 eyes underwent foldable IF-PIOL and 15 eyes underwent nonfoldable IF-PIOL implantation. At one year after the operation, 92% of foldable treated eyes and 53% of nonfoldable treated eyes were within ±1D of the intended emmetropia (p=0.04). The mean preoperative and postoperative first year best corrected visual acuity (BCVA) was 0.25±0.26 and 0.13±0.21for foldable treated eyes and 0.41±0.31ve 0.19±0.11 for nonfoldable treated eyes (p>0.05).
Conclusion: While the percent of eyes within the intended spheric equivalent was statistically higher for foldable lens to correct high myopia, postoperative final BCVA, central endothelial cell loss, cylinder power, and intraocular pressure were not statistically significant between foldable and nonfoldable lenses
Keywords : Artisan, artiflex, iris-fixated phakic intraocular lens, endothelial cell loss, spheric equivalent