ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2006 , Vol 1 , Num 2
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Evaluation of Anterior Chamber Depth by Corneal Topography and Keratometry Methods
Ahmet ÖZER1, Meltem ŞORABATUR1, Afsun ŞAHİN1, Sumru YURDAKUL1
Osmangazi Üni. Tıp Fak. Göz Hast. A.D., Eskişehir Purpose: To evaluate the anterior chamber depth (ACD) of a normal population by corneal topography and keratometry and to compare the results of these methods.

Materials and Methods: Fifty healthy subjects who have no history of an eye disease and surgery were included in the study. Of the 50 subjects, 32 were female and 18 were male. The average age of the subjects was 37.6±11.3 . Three consecutive measurements of ACD were obtained by using Orbscan II corneal topography system and the mean of the 3 readings was used. Theoric ACD values were calculated with the special formula ACD=[((k1+k2)/2)x0.29]+0.5 using keratometric values obtained by Javal keratometry. Iris-lens diaphragm has been found mildly concave backwards and it has been found that iris-lens diaphragm lies 1.0 mm behind the corneal arc instead of being 0.5 mm. New theoric ACD values were calculated by using the constant 1.0 instead of 0.5 in the formula, which is used for ACD calculation. Right and left eyes were analyzed separately.

Results: ACD values obtained by Orbscan II topography were 3.32±0.31 mm for the right eye and 3.33±0.32 mm for the left eye. Theroic ACD values that were calculated following keratometric measurements were 2.78±0.46 mm for the right eye and 2.79±0.43 mm for the left eye. New theroic ACD values were 3.28±0.46 mm for the right eye, and 3.29±0.43 mm for the left eye. No statistical difference was found between ACD values obtained by Orbscan II topography and new theoric ACD values.

Conclusion: Theoric ACD values calculated from the data that were obtained by using keratometry give the ACD values which should be proper for this eye. If the values obtained via this measurement are compared to the other values obtained by using different measurement methods and if it is determined any kind of change in anterior chamber depth, the situations in which iris-lens diaphragm moves forward or backward can be enlightened more easily. Keywords : anterior chamber depth, corneal topography, keratometry