ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2008 , Vol 3 , Num 4
Turkish Abstract Abstract PDF Similar Articles Mail to Author
The Effect of Controlled Systemic Hypertension with Treatment on Intraocular Pressure and Ocular Pulse Amplitude
Remzi KARADAĞ1, Mehmet KANBAY2
1Fatih Üniversitesi Tıp Fakültesi Göz Hastalıkları A.D., Ankara, Yrd. Doç. Dr.
2Fatih Üniversitesi Tıp Fakültesi Nefroloji Bölümü, Ankara, Uzm. Dr.
Purpose: To compare the intraocular pressure (IOP) and ocular pulse amplitude (OPA) between the patients with systemic hypertension and normal individuals.
Materials and Methods: Thirty-three patients with controlled systemic hypertension with treatment and 24 healthy subjects were included in the study. All participants underwent 24-hour ambulatory blood pressure monitoring, IOP and OPA measurements with dynamic contour tonometry. Statistically analysis of the groups was also performed according to mean IOP, OPA, systolic blood pressure (SBP) and diastolic blood pressure (DBP).
Results: The mean age of the 33 patients (23 female/10 male) was 53.0±11.7 years in hypertension group. Mean IOP was 16.8±2.1 mmHg, OPA was 2.9±1.0 mmHg, SBP was 125.9±10.8 mmHg and DBP was 81.3±9.9 mmHg in this group. In control group, the mean age of the 24 subjects (14 female / 10 male) was 49.9±10.3 years. Mean IOP was16.1±1.9 mmHg, OPA was 2.5±0.7 mmHg, SBP was 122±8.7 mmHg and DBP was 81.0±7.3 mmHg in this group. There was no statistically significant difference between the groups in terms of the other parameters except for OPA.
Conclusion: However, patients with controlled systemic hypertension had higher the OPA values than normal individuals, both groups had similar the SBP, DBP and IOP values. The elevated OPA values in the patients with systemic hypertension are most likely secondary to increased choroidal perfusion and ocular blood flow.
Keywords : Blood pressure, intraocular pressure, ocular pulse amplitude, systemic hypertension