ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2008 , Vol 3 , Num 1
Turkish Abstract Abstract PDF Similar Articles Mail to Author
Comparison of Polypropylene and Silicone Ahmed Glaucoma Valves in Neovascular Glaucoma Cases
Muhittin TAŞKAPILI1, Cemil YILMAZLI1, Selim KOCABORA2, Kübra ŞEREFOĞLU3, Mustafa ÖZSÜTÇÜ3, Erhan GÖÇMEZ3
1Vakıf Gureba EAH Göz Kliniği Başasistanı, İstanbul, Uzm. Dr.
2Vakıf Gureba EAH Göz Kliniği Şef Muavini, İstanbul, Uzm. Dr.
3Vakıf Gureba EAH Göz Kliniği, İstanbul, Asist. Dr.
Purpose: To compare and evaluate the clinical results of silicone (FP-7) and polypropylene (S-2) Ahmed glaucoma valves (AGV) in neovascular glaucoma cases.
Materials and Methods: 26 eyes of 21 patients with neovascular glaucoma were included into study. In 14 eyes polypropylene (model S-2) (group 1) and in 12 eyes silicone (model FP-7) AGV were implanted. All cases were performed under local anesthesia. After fornix-based conjunctival flap was created the valve was positioned 10-12 mm posterior to the limbus in the superotemporal quadrant.
Results: The patients were followed up one year. The mean age was 65.42±12.81 years (28-83 years) in group 1 and 57.58±17.21 years (25-77 years) in group 2 (p=0.216). Preoperative mean intraocular pressures (IOP) under medication were 45.46±14.60 mmHg (29-65 mmHg) and 48±8.27 mmHg (37-60 mmHg), respectively group 1 and group 2 (p=0.429). Preoperative visual acuities were between light perception (+) and 1/10 in both groups.Postoperative mean IOP at the end of one year were 18.07±3.81 mmHg and 17.58±4.44 mmHg, respectively group 1 and group 2 (p=0.938). After the operation the number of glaucoma drugs were statistically decreased in both groups (respectively p=0.007 and p=0.01). Hypotony and shallow anterior chamber were observed in 6 eyes (42.8%) in group 1 and 5 eyes (41.6%) in group 2. In group 1 two choroidal detachments and two hyphemas and in group 2 two choroidal detachments and one hyphema were observed. Regarding complications and visual acuities there were no statistically significant difference (p=1.00). In first year surgical success 64.2% in group 1 and 66.6% in group 2 (p=1.00).
Conclusion: In neovascular glaucoma cases it was observed that there was no difference regarding IOP reduction and complications between either AGV.
Keywords : Ahmed glaucoma valve, neovascular glaucoma