ISSN : 3023-7505
  • Home
  • About
    • About The Journal
    • Instructions for Authors
    • Privacy Policy
    • Reviewer Process
    • Research and Publication Ethics
  • Editorial Board
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2026 , Vol 21 , Num 3
Abstract Free Full Text Similar Articles Mail to Author
Early Effects of Latanoprostene Bunod on Optical Coherence Tomography and Optical Coherence Tomography Angiography in Glaucoma and Ocular Hypertension
Zeynep Kirişçi1, Diğdem Tetik1, İrem Kar2, Oya Tekeli1
1Ankara University Faculty of Medicine, Ophthalmology, Ankara, Türkiye
2Ankara University Faculty of Medicine, Department of Biostatistics, Ankara, Türkiye
DOI : 10.37844/TJ-CEO.2026.21.12 Purpose: To evaluate optical coherence tomography (OCT) and optical coherence tomography angiography (OCTA) parameters in open-angle glaucoma (OAG) and ocular hypertension (OHT) patients using latanoprostene bunod (LBN).

Patients and Methods: The study included treatment-naive patients diagnosed with OAG or OHT between June 2023 and May 2024. Intraocular pressure (IOP), OCT and OCTA images were evaluated at baseline, 3 months and 6 months after LBN treatment.

Results: The diagnosis was OHT in 40 eyes (83.3%) and OAG in 8 eyes (16.7%). The mean IOP was 25.4±5.3 mmHg before and 17.3±3.0 and 17.8±3.7 mmHg at months 3 and 6 after LBN treatment, respectively (p<0.001 for each visit compared to baseline). No statistically significant difference was observed between baseline and follow-up visits when comparing OCT and OCTA parameters. A moderate positive statistically significant correlation existed between the pre-treatment average ganglion cell layer-inner plexiform layer (GCL-IPL) thickness, minimum GCL-IPL thickness, average retinal nerve fiber layer thickness with the radial peripapillary capillary flux index (RPC-FI) measured at the final examination (r=0.519, p<0.001; r=0.543, p<0.001; r=0.499, p<0.001).

Conclusions: In our study, the decrease in IOP was found to be statistically significant, while the changes in OCT and OCTA parameters were not found to be significant. A statistically significant positive correlation existed between the baseline OCT parameters and the final RPC-FI in OCTA. This result may indicate the importance of the RPC-FI in follow-up. Keywords : flux index; latanoprostene bunod; ocular hypertension; open-angle glaucoma; optical coherence angiography tomography

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About
Editorial Board
Contact