ISSN : 3023-7505
  • Home
  • About The Journal
  • Editorial Board
  • Instructions for Authors
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Automated Perimetry
Carbonic Anhydrase Inhibitors
Intra Ocular Lens Power Calculation and Optic Biometry...
Visual Field Defects in Glaucoma
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
Current Minimal Invasive Angle Procedures Without Implants for the Treatment of Glaucoma...
Intra Ocular Lens Power Calculation and Optic Biometry...
Automated Perimetry
Carbonic Anhydrase Inhibitors
Visual Field Defect and Retinal Nerve Fiber Layer Defect in a Case of Optic Nerve Head Drusen...
PureSee Kesintisiz Yüksek Kalitede Görüş
TJ-CEO 2024 , Vol 19 , Num 3
Abstract Free Full Text Similar Articles Mail to Author
Comparison of different formulas in Panoptix intraocular lens power calculations using Pentacam Oculus AXL
Faruk Kaya1, Haci Koc2, Mustafa Eliacik3, Ali Aydin4
1Assoc.Prof.,MD, Department of Ophthalmology, Istanbul Medipol University Faculty of Medicine; Medipol Bahcelievler Hospital, Istanbul, Türkiye
2MD, Department of Ophthalmology, Dunya Goz Hastanesi, Sakarya, Türkiye
3Prof., MD,Department of Ophthalmology, Istanbul Medipol University Faculty of Medicine; Medipol Kosuyolu Hospital,Istanbul,Türkiye
4Prof., MD, Department of Ophthalmology, Near East University Faculty of Medicine, Near East Boulevard Nicosia / TRNC, Mersin 10, Türkiye
DOI : 10.37844/TJ-CEO.2024.19.17 Purpose: To evaluate and compare the predictability of different formulas for multifocal intraocular lens (IOL) power calculation using a new optical biometer (Pentacam Oculus AXL).

Materials and Methods: This retrospective study included 70 eyes of 38 patients who underwent uneventful phacoemulsification with multifocal IOL (AcrySof IQ PanOptix) implantation. IOL power calculations were performed using Pentacam Oculus AXL optical biometer. Postoperative actual refractive errors and errors predicted by the Barrett Universal II, Olsen, SRK/T, Holladay 1, Hoffer Q and Haigis formulas were analyzed. The mean estimation error (EE), mean absolute estimation error (AEE) and the percentage of eyes within ±0.50 and ±1.00 D of target refraction of for each of six formulas were calculated and compared in three groups formed based on the axial length(AL) (Group 1: <22.5mm, Group 2: 22.5-24mm, Group 3: >24mm).

Results: In overall study group, the smallest mean AEE was provided by Barrett Universal II formula, with no statistically significant difference (p=0.23). The highest percentage of eyes within ±0.50 and ±1.00 D of target refraction was also found by using Barrett Universal II (78% and 95%). SRK/T provided smallest mean AEE for group 1(p=0.42). In Group 2, the smallest mean AEE was obtained by using Barrett Universal II (p=0.10). In group 3, Haigis provided smallest mean AEE (p=0.14).

Conclusions: Based on the Pentacam Oculus AXL biometric data, better results obtained using SRK/T formula in eyes with short AL. Barrett Universal II formula can be preferred in eyes with moderate AL, and Haigis formula in eyes with long AL. Keywords : Pentacam Oculus AXL, axial length, multifocal IOL power, calculation formulas

PureSee Kesintisiz Yüksek Kalitede Görüş
Home
About The Journal
Editorial Board
Instructions for Authors
Contact